Polwax Global

Temperature & Humidity Transmitters

RHT210 / RHT211 Transmitter with External Sensor

RHT210 TR / RHT210 ES / RHT211 TR

Temperature and humidity transmitter with external 150 mm stainless-steel probe and filter, with or without display, 4–20 mA and RS485 Modbus RTU.

Probe
150 mm SS with SS filter
Outputs
4–20 mA, RS485 / 0–10 V optional
Supply
24 VDC
Protection
IP54

Overview

Available as 3 versions: RHT210 TR, RHT210 ES and RHT211 TR.

Typical applications: HVAC & ducts, clean rooms, storage & warehouses, industrial processes.

Key features

  • External 150 mm stainless-steel probe with SS filter
  • Versions with and without display
  • 4–20 mA and RS485 Modbus RTU outputs, 0–10 V optional
  • Duct mounting

Technical specifications

Measurement ranges & outputs
InputsTemperature & humidity
Output4-20 mA, RS485 Modbus RTU / 0-10 V (optional)
General
DisplayWith & without display
LanguageEnglish
Power supply & connectivity
Supply voltage24 VDC
Installation & environment
ProbeSS probe length 150 mm, SS filter
MountingDuct mount
Dimensions75 × 35 × 75 mm
Protection classIP54
Media compatibilityAir, non-combustible, non-corrosive gases

Specifications are subject to change. Please check the current datasheet or ask our team before ordering.

Models and ordering information

ModelDescription
RHT210 TR
RHT210 ES
RHT211 TR

Applications and industries

  • HVAC & ducts
  • Clean rooms
  • Storage & warehouses
  • Industrial processes

Application guides

Application Demonstrations

An interactive example of how the instrument is used. Try the Normal, Warning and Alarm conditions.

HVAC & building services

HVAC duct monitoring

Report supply-air conditions from ducts to the building management system using a stainless-steel probe.

Illustration: HVAC duct monitoring, with numbered measurement points
Illustrative simulation — not live instrument data. The interactive version needs JavaScript.

Illustrative simulation — not live instrument data.

Measurement points

  1. Probe tip in the air stream
  2. RHT DM housing on the duct
  3. Signal to the BMS

Monitoring workflow

  1. RHT DM transmitters are mounted on the duct with a 150, 300 or 400 mm stainless-steel probe.
  2. The probe sits in the air stream and measures temperature and humidity.
  3. Outputs are 4–20 mA, 0–10 V or RS485 Modbus RTU.
  4. The BMS uses the values in its own control loops.

Products used

Air conditions and the supply-air limits in the simulation are illustrative.

Related products

Enquiry

Ask about the RHT210 / RHT211 Transmitter with External Sensor

Tell us what you need to measure, the range and the installation. Our technical team will reply with a recommendation and quotation.

Fields marked * are required.