Pharma & life sciences
Cleanroom pressure cascade
Maintain airflow from cleaner to less clean rooms and detect when airflow stops.

Interactive application demo
An interactive example of how the instrument is used. Try the Normal, Warning and Alarm conditions.
Pharma & life sciences
Cleanroom pressure cascade
Maintain airflow from cleaner to less clean rooms and detect when airflow stops.
Illustrative simulation — not live instrument data.
Measurement points
- Pressure tap in the cleanroom (+ port, P1)
- − port open to the corridor (reference P2)
- DPT30 transmitter on the corridor wall
- Signal to the BMS, PLC or data logger
Monitoring workflow
- The + port is piped to a tap in the cleanroom, the − port is open to the corridor.
- The transmitter measures the difference (ΔP = P1 − P2) in Pa or mm WC, with a 500 ms response time.
- The value goes out as 4–20 mA, 0–10 V, relay or RS485 Modbus RTU, depending on model and order code.
- Alarm versions sound a buzzer at the door; your BMS, PLC or data logger records the trend.
Monitoring only: the transmitters measure and signal. Room-pressure control and door interlocks are done by your own systems.
The monitoring challenge
Maintain airflow from cleaner to less clean rooms and detect when airflow stops.
- Door openings, filter loading and ventilation changes can disturb the pressure relationship between rooms.
- Room-to-room pressure differences are small, so instruments must resolve low ranges.
- Staff need a warning when the intended pressure relationship is not maintained.
How POLWAX instruments help
What the recommended instruments provide
DPT30 Differential Pressure Transmitter: Panel-mount differential pressure transmitter with ranges up to 0–700 mm WC, alarm, 4–20 mA, 0–10 V, RS485 Modbus RTU and relay options.
DPT20 Differential Pressure Transmitter: Panel-mount differential pressure transmitter for air and non-corrosive gases, ranges up to 0–250 mm WC, with buzzer or 4–20 mA output.
DPT50 WM High-Precision Differential Pressure Transmitter: High-precision differential pressure transmitter for filter, fan and air-flow monitoring in HVAC/R, configurable over USB; DPH100 WM adds temperature and humidity.
Recommended instruments
Products for this application

DPT30
DPT30 Differential Pressure Transmitter
Panel-mount differential pressure transmitter with ranges up to 0–700 mm WC, alarm, 4–20 mA, 0–10 V, RS485 Modbus RTU and relay options.
- Range
- Up to 0–700 mm WC
- Accuracy
- ±0.5 % FS (≥ 0–25 mm WC)
- Outputs
- 4–20 mA, 0–10 V, RS485, relay
Suited to: HVAC systems – airflow and filter monitoring, Clean rooms – contamination prevention, Industrial processes – filter and pump monitoring

DPT20
DPT20 Differential Pressure Transmitter
Panel-mount differential pressure transmitter for air and non-corrosive gases, ranges up to 0–250 mm WC, with buzzer or 4–20 mA output.
- Range
- Up to 0–250 mm WC
- Accuracy
- ±0.5 % FS (≥ 0–25 mm WC)
- Output
- Buzzer or 4–20 mA
Suited to: HVAC systems – airflow and filter monitoring, Clean rooms – contamination prevention, Industrial processes – filter and pump monitoring

DPT50 WM / DPT100 WM / DPH100 WM
DPT50 WM High-Precision Differential Pressure Transmitter
High-precision differential pressure transmitter for filter, fan and air-flow monitoring in HVAC/R, configurable over USB; DPH100 WM adds temperature and humidity.
- Accuracy
- 0.25 % / 0.5 % of FS
- Outputs
- 4-20 mA / 0-10 V, RS485
- Config
- USB
Suited to: Building automation (HVAC/R), Air filter monitoring, Fan and air-flow monitoring
Pharma & life sciences
Related applications
Ultra-low temperature freezers
Record ultra-low freezer temperatures with only the probe inside the freezer and the logger outside.
Vaccine & medicine refrigerators
Log refrigerator temperatures at every interval with a reusable logger and produce PDF reports on connection.
Consultation
Discuss your application with our team
Describe what you need to monitor and where. We will suggest suitable instruments and options.