Maintain airflow from cleaner to less clean rooms and detect when airflow stops.

POLWAX DPT30 panel-mount differential pressure transmitter

Interactive application demo

An interactive example of how the instrument is used. Try the Normal, Warning and Alarm conditions.

Pharma & life sciences

Cleanroom pressure cascade

Maintain airflow from cleaner to less clean rooms and detect when airflow stops.

Illustration: Cleanroom pressure cascade, with numbered measurement points
Illustrative simulation — not live instrument data. The interactive version needs JavaScript.

Illustrative simulation — not live instrument data.

Measurement points

  1. Pressure tap in the cleanroom (+ port, P1)
  2. − port open to the corridor (reference P2)
  3. DPT30 transmitter on the corridor wall
  4. Signal to the BMS, PLC or data logger

Monitoring workflow

  1. The + port is piped to a tap in the cleanroom, the − port is open to the corridor.
  2. The transmitter measures the difference (ΔP = P1 − P2) in Pa or mm WC, with a 500 ms response time.
  3. The value goes out as 4–20 mA, 0–10 V, relay or RS485 Modbus RTU, depending on model and order code.
  4. Alarm versions sound a buzzer at the door; your BMS, PLC or data logger records the trend.

Monitoring only: the transmitters measure and signal. Room-pressure control and door interlocks are done by your own systems.

The monitoring challenge

Maintain airflow from cleaner to less clean rooms and detect when airflow stops.

  • Door openings, filter loading and ventilation changes can disturb the pressure relationship between rooms.
  • Room-to-room pressure differences are small, so instruments must resolve low ranges.
  • Staff need a warning when the intended pressure relationship is not maintained.

How POLWAX instruments help

What the recommended instruments provide

  • DPT30 Differential Pressure Transmitter: Panel-mount differential pressure transmitter with ranges up to 0–700 mm WC, alarm, 4–20 mA, 0–10 V, RS485 Modbus RTU and relay options.

  • DPT20 Differential Pressure Transmitter: Panel-mount differential pressure transmitter for air and non-corrosive gases, ranges up to 0–250 mm WC, with buzzer or 4–20 mA output.

  • DPT50 WM High-Precision Differential Pressure Transmitter: High-precision differential pressure transmitter for filter, fan and air-flow monitoring in HVAC/R, configurable over USB; DPH100 WM adds temperature and humidity.

Recommended instruments

Products for this application

Pharma & life sciences

Related applications

Consultation

Discuss your application with our team

Describe what you need to monitor and where. We will suggest suitable instruments and options.

Fields marked * are required.