Differential Pressure Transmitters
DPT30 Differential Pressure Transmitter
DPT30
Panel-mount differential pressure transmitter with ranges up to 0–700 mm WC, alarm, 4–20 mA, 0–10 V, RS485 Modbus RTU and relay options.
- Range
- Up to 0–700 mm WC
- Accuracy
- ±0.5 % FS (≥ 0–25 mm WC)
- Outputs
- 4–20 mA, 0–10 V, RS485, relay
- Mounting
- Panel mounting
Overview
Typical applications: HVAC systems – airflow and filter monitoring, clean rooms – contamination prevention, industrial processes – filter and pump monitoring, building automation – smart ventilation systems.
Key features
- Ranges from 0–10 to 0–700 mm WC, bi-directional
- Alarm with inbuilt buzzer
- 4–20 mA, 0–10 V, RS485 Modbus RTU and relay options
- Configuration via keys
- Panel mounting
Technical specifications
| Measuring ranges (order code) | 0 - 10 / 0 - 25 / 0 - 50 / 0 - 100 / 0 - 150 / 0 - 200 / 0 - 250 / 0 - 500 / 0 - 700 mm WC (all ranges bi-directional) |
|---|---|
| Output options (order code) | None, alarm, 0 - 10 V, 4 - 20 mA, relay, RS485 |
| Accuracy (from applied pressure) | Ranges ≤ 0 - 10 mm WC: ±1.0 % of FS · ranges ≥ 0 - 25 mm WC: ±0.5 % of FS |
| Measuring units | Pa & mmWC |
| Response time | 500 ms |
| Over pressure | Ranges ≤ 50 mm WC: 9 PSI · 100 to 1000 mm WC: 19 PSI |
| Media compatibility | Air, non-combustible, non-corrosive gases |
| Alarm | Buzzer |
|---|---|
| Switch | Digital push button |
| Communication | RS485 Modbus RTU |
|---|---|
| Supply voltage | 12 - 24 VDC |
| Signal connection | 3 wire |
| Load resistance | 47 to 470 Ω @ 24 VDC |
| Electrical connections | Screw terminals |
| Process connection | Push-on connection for 3/16" ID tubing |
|---|---|
| Mounting | Panel mounting |
| Enclosure | ABS |
Specifications are subject to change. Please check the current datasheet or ask our team before ordering.
Models and ordering information
| Model | Description |
|---|---|
| DPT30 | Ranges 0–10 to 0–700 mm WC; alarm, 4–20 mA, 0–10 V, RS485 Modbus RTU and relay options |
Applications and industries
- HVAC systems – airflow and filter monitoring
- Clean rooms – contamination prevention
- Industrial processes – filter and pump monitoring
- Building automation – smart ventilation systems
Application guides
-
Cleanroom pressure cascade
Maintain airflow from cleaner to less clean rooms and detect when airflow stops.
-
Air filter monitoring
Track pressure drop across the filter so replacement occurs at the right time.
Application Demonstrations
Interactive examples of how this instrument is used. Choose an application, then try the Normal, Warning and Alarm conditions.
Pharma & life sciences
Cleanroom pressure cascade
Maintain airflow from cleaner to less clean rooms and detect when airflow stops.
Illustrative simulation — not live instrument data.
Measurement points
- Pressure tap in the cleanroom (+ port, P1)
- − port open to the corridor (reference P2)
- DPT30 transmitter on the corridor wall
- Signal to the BMS, PLC or data logger
Monitoring workflow
- The + port is piped to a tap in the cleanroom, the − port is open to the corridor.
- The transmitter measures the difference (ΔP = P1 − P2) in Pa or mm WC, with a 500 ms response time.
- The value goes out as 4–20 mA, 0–10 V, relay or RS485 Modbus RTU, depending on model and order code.
- Alarm versions sound a buzzer at the door; your BMS, PLC or data logger records the trend.
Products used
DPT30 Differential Pressure Transmitter This product
DPT20 Differential Pressure Transmitter
DPT50 WM High-Precision Differential Pressure Transmitter
Monitoring only: the transmitters measure and signal. Room-pressure control and door interlocks are done by your own systems.
HVAC & building services
Air filter monitoring
Track pressure drop across the filter so replacement occurs at the right time.
Illustrative simulation — not live instrument data.
Measurement points
- + port upstream of the filter
- − port downstream of the filter
- DPT20 transmitter on the air-handling unit
Monitoring workflow
- The + port is connected upstream of the filter, the − port downstream.
- The transmitter measures the pressure difference across the filter.
- DPT20 is available with an inbuilt buzzer or a 4–20 mA output; DPT50 WM adds RS485 Modbus RTU and USB configuration.
- The BMS trends the value and raises a maintenance alarm at your limit.
Products used
DPT20 Differential Pressure Transmitter
DPT50 WM High-Precision Differential Pressure Transmitter
DPT30 Differential Pressure Transmitter This product
Filter pressure values and the replacement limit are illustrative; use the filter manufacturer's data.
Documents and software
Related products

DPT20
DPT20 Differential Pressure Transmitter
Panel-mount differential pressure transmitter for air and non-corrosive gases, ranges up to 0–250 mm WC, with…

DPT50 WM / DPT100 WM / DPH100 WM
DPT50 WM High-Precision Differential Pressure Transmitter
High-precision differential pressure transmitter for filter, fan and air-flow monitoring in HVAC/R, configurable over USB; DPH100…

RHT50 WM
RHT50 WM Temperature & Humidity Transmitter
Wall-mount temperature and humidity transmitter: ±0.4 °C, ±1.8 % RH, two analogue outputs, RS485 Modbus RTU,…

RHT100
ClimaTRANS RHT100 Temperature & Humidity Transmitter
Industrial temperature and humidity transmitter with TFT display, RS485 Modbus RTU and wall or duct mounting.
Enquiry
Ask about the DPT30 Differential Pressure Transmitter
Tell us what you need to measure, the range and the installation. Our technical team will reply with a recommendation and quotation.