Polwax Global

Sound Level & Lux Transmitters

SL50 Sound Level Transmitter

SL50

Noise transmitter measuring 30–120 dB at ±1.5 dB accuracy, with 4–20 mA, 0–10 V or RS485 Modbus RTU outputs and IP65 housing.

Range
30 dB to 120 dB
Accuracy
±1.5 dB
Outputs
4–20 mA, 0–10 V, RS485
Protection
IP65

Overview

Typical applications: factories & worker safety, airports, traffic & smart-city noise monitoring, hospitals, educational institutions.

Key features

  • Measuring range 30–120 dB, resolution 0.1 dB
  • Precision electret condenser microphone
  • 4–20 mA, 0–10 V or RS485 Modbus RTU output
  • Wall or pole mounting
  • IP65 industrial ABS housing

Technical specifications

Measurement ranges & outputs
Measurement range30 dB to 120 dB
Accuracy±1.5 dB
Resolution0.1 dB
Response time≤30 seconds
Frequency range20 Hz – 20 kHz
Microphone typePrecision electret condenser microphone
Output options4-20 mA, 0-10 V, RS485 (Modbus RTU)
Power supply & connectivity
Communication protocolModbus RTU
Power supply12 V – 24 V DC
Installation & environment
Mounting optionsWall mount, pole mount
Housing materialIndustrial-grade ABS
Protection ratingIP65 (water-resistant and dustproof)
Operating temperature-10 °C to 60 °C
Storage temperature-20 °C to 80 °C
Humidity range0–95 % RH (non-condensing)
Order code
Output 000-10 V
Output 01RS485
Output 024 - 20 mA
Range 10130 - 120 dB

Specifications are subject to change. Please check the current datasheet or ask our team before ordering.

Models and ordering information

ModelDescription
SL5030–120 dB; output code 00 / 01 / 02; example order code SL50 -01-101

Applications and industries

  • Factories & worker safety
  • Airports
  • Traffic & smart-city noise monitoring
  • Hospitals
  • Educational institutions

Application guides

Application Demonstrations

An interactive example of how the instrument is used. Try the Normal, Warning and Alarm conditions.

Factory & utilities

Workplace noise level

Report hall sound levels from 30 to 120 dB with a fixed transmitter.

Illustration: Workplace noise level, with numbered measurement points
Illustrative simulation — not live instrument data. The interactive version needs JavaScript.

Illustrative simulation — not live instrument data.

Measurement points

  1. SL50 on the wall of the hall

Monitoring workflow

  1. SL50 is mounted on a wall or pole in the area to be monitored.
  2. It measures 30–120 dB with ±1.5 dB accuracy over 20 Hz – 20 kHz.
  3. The value is output as 4–20 mA, 0–10 V or RS485 Modbus RTU.
  4. Displays or the BMS show the level and apply your limits.

Products used

  • SL50 Sound Level Transmitter This product

Machine noise levels and the 80 / 85 dB example limits are illustrative.

Documents and software

Related products

Enquiry

Ask about the SL50 Sound Level Transmitter

Tell us what you need to measure, the range and the installation. Our technical team will reply with a recommendation and quotation.